Products
PRODUCTS DETAILS
Home > Products >
Low Voltage Busway And Bus Duct 630A-6300A Electrical Busway Low Voltage

Low Voltage Busway And Bus Duct 630A-6300A Electrical Busway Low Voltage

MOQ: 1
Price: 701-70001 USD per set
Standard Packaging: Standard Packaging
Delivery Period: Expected shipment within 30 days after successful payment
Payment Method: D/P T/T
Supply Capacity: 5000 units per year
Detail Information
Place of Origin
Shenzhen, Guangdong, China
Brand Name
HUAHUI
Certification
UN38.3、UL、CE、KC、FCC、PSE、FDA和MSDS
Product Name:
Electrical Busduct
Type:
Busduct System
Feature:
Enclosed
Protection Grade:
IP54, IP66
Advantage:
Safety, Aesthetics
Application:
Large Factories, Mining Enterprises, Substations
Highlight:

630A Busway And Bus Duct

,

6300A Low Voltage Busway

,

6300A Electrical Busway Low Voltage

Product Description
630A-6300A Aluminum Magnesium Alloy Electrical Busduct Low Voltage Enclosed Bus Duct
We offer a wide range of busbar trunking products and can tailor solutions to meet your specific needs. Contact us via email or WhatsApp for assistance.
Selection Parameters and Technical Parameters of Dense Bus Duct
Current level XLC /4P W(mm) XLC /4P H(mm) XLC /5P W(mm) XLC /5P H(mm)
400 128 98 128 98
500 128 108 128 108
630 128 123 128 123
800 128 138 128 138
1000 128 158 128 158
1250 128 183 128 183
1600 128 218 128 218
2000 128 268 128 268
2500 128 280 128 280
3200 128 400 128 400
4000 128 490 128 490
Low Voltage Busway And Bus Duct 630A-6300A Electrical Busway Low Voltage 0
Technical Parameters of XLC Type Bus Duct
Execution standards IEC60439.1-2000 IEC60439.2-2000 GB/T 7251.6-2015
Ambient temperature -5/+40°C (24-hour average not exceeding 35°C)
Altitude Not exceeding 2000M
Protection grade IP54, IP66
Unit Length (M) Choose between 1.6, 2.5, 3.2, 6 (0.5-6)
Rated operational voltage (V) 690V (with tap unit)/1000V (without tap unit)
Rated insulation voltage (Ui) (V) 800V (with tap unit)/1000V (without tap unit)
Frequency (HZ) 50-60
Rated current (A) 400 | 630 | 800 | 1000 | 1250 | 1600 | 2000 | 2500 | 3150 | 4000 | 5000
Resistance (uΩ/m) 88.9 | 71.1 | 56.4 | 40.3 | 33.2 | 24.5 | 19.5 | 14.5 | 11.3 | 8.9 | 6.7
Reactance (uΩ/m) 66.5 | 62.2 | 39.1 | 37.9 | 46.6 | 30.1 | 7.4 | 25.9 | 25.3 | 14.3 | 13
Total Reactance (uΩ/m) 289.7 | 289.7 | 184.2 | 176.3 | 221.6 | 150.7 | 130.7 | 129.6 | 120.9 | 76.2 | 69
Voltage drop (mV/m) 77.5 | 81 | 77.3 | 77.5 | 76.4 | 74.9 | 73.3 | 71.4 | 69.7 | 63 | 61.4
Rated short-time withstand current (KA) 30 | 30 | 50 | 50 | 80
Rated peak withstand current (KA) 63 | 63 | 105 | 105 | 176
Temperature rise (K) ≤70
Insulation resistance (MΩ) ≥20
Electrical clearance (mm) ≥10.0mm (with tapping unit)/≥14.0mm (without tapping unit)
Creepage (mm) ≥12.5mm (with tap cell)/≥16.0mm (without tap cell)
Protection circuit effectiveness (Ω) <0.02
Dielectric properties 50Hz, 3750v/min, no breakdown, flashover
Installation method Vertical or horizontal
Number of plug-in interfaces Minimum 0.5/m pieces (double-sided plug available)
Maximum fixed spacing (m) 4 | 4 | 3 | 3
Balanced load (kg/m) 20 | 20 | 25 | 30
Concentrated load (kg) 90 | 90 | 90 | 90
Key Features
  • Safety, aesthetics, and reliability
  • Strong overload capacity
  • Low temperature rise
  • Excellent load capacity and dynamic/thermal stability
  • Eliminates uneven current distribution in spliced high-voltage cables
  • Double-grounded shell for high safety
  • Good short-circuit resistance with low energy consumption
  • Easy maintenance, disassembly, and assembly
Field of Application
Power supply systems for large factories, mining enterprises, substations, captive power plants, from generators to transformers and high-voltage distribution rooms.
Low Voltage Busway And Bus Duct 630A-6300A Electrical Busway Low Voltage 1
Casted Busway Features
  • Capacity from 100A to 4000A
  • Protection level up to IP68 (100% waterproof/dustproof)
  • Epoxy resin casting prevents metal oxidation/corrosion
  • High structural strength with good mechanical properties
  • Compact design with strong dynamic/thermal stability
  • Suitable for harsh indoor/outdoor environments
  • Capable of continuous overload operation
Field of Application
Power plants, substations, shipbuilding, paper mills, ports, basements, petrochemical, steel, coal mines, and other harsh environments.

Fire-Resistant Features
  • 180-minute fire-resistant duration
  • Compact structure with small size
  • Fire-resistant paint and baffles prevent flame penetration
  • Low impedance with excellent dynamic/thermal stability
  • Easy maintenance and assembly
  • Withstands temperatures up to 1000°C
  • Excellent electrical conductivity
  • Suitable for fire risk areas requiring continuous power
Field of Application
Schools, hospitals, hotels, financial buildings, offices, urban rail transit, government buildings, libraries, textile and mining enterprises.
Low Voltage Busway And Bus Duct 630A-6300A Electrical Busway Low Voltage 2
Advanced Structural Features
  • Ultra-thin, compact design with industry-leading copper specifications
  • 360° protection against dust, corrosion, moisture, and impact
  • "Sandwich" structure combining shell, insulation, and conductor
  • Unique sawtooth design with large heat dissipation surface
  • Dual neutral system for safer operation
  • Non-magnetic shell eliminates eddy current interference
Field of Application
Shopping malls, schools, industrial plants, rail transit, commercial complexes, real estate, data centers, hospitals, and hotels.
Low Voltage Busway And Bus Duct 630A-6300A Electrical Busway Low Voltage 3