The ZTE ZXDU58 B121 is a high-performance single-output embedded DC power system developed for telecom cabinet and communication infrastructure applications. It supports 220V and 380V AC input and delivers a stable 48V DC output with a maximum total current of 120A and output power over 500W. Featuring a wide operating voltage range, high power factor, and excellent anti-interference capability, this power system integrates complete power distribution, lightning protection, and multi-level protection functions. Adopting mature digital control technology and modular design, it runs stably under harsh working conditions. It is widely used in communication base stations, indoor machine rooms, and various cabinet-type telecom equipment, serving as a reliable core power solution for global telecommunication networks.
| Category | Item | Parameter |
|---|---|---|
| Basic Info | Product Type | Single Output Embedded Telecom DC Power System |
| Brand | ZTE | |
| Model | ZXDU58 B121 | |
| Application | Cabinet Frame, Telecom Equipment | |
| AC Input | Rated Input Voltage | 220V AC / 380V AC |
| Operating Voltage Range | 80V ~ 300V AC | |
| Input Frequency | 50Hz / 60Hz | |
| Max Input Current | 100A | |
| Power Factor | ≥ 0.99 (Full Load) | |
| DC Output | Nominal Output Voltage | 48V DC (Adjustable: 42V ~ 58V DC) |
| Max Total Output Current | 120A | |
| Total Output Power | > 500W | |
| Output Type | Single | |
| DC Load Circuits | 6 channels (6A ~ 63A per channel) | |
| Battery Input | Battery Input | 2 channels (100A circuit breaker) |
| Performance | Overall Efficiency | ≥ 90% (Rated Input & Full Load) |
| Ripple Voltage | Peak to peak ≤ 150mV (20MHz bandwidth) | |
| Lightning Protection | Class C Discharge Current | ≤ 40kA |
| Class D Discharge Current | ≤ 20kA | |
| Physical Parameter | Dimension (H×W×D) | 265.6mm × 482.6mm × 350mm (6U) |
| Full Configuration Weight | 32.7kg | |
| Working Environment | Operating Temperature | -40℃ ~ +55℃ |
| Storage Temperature | -40℃ ~ +70℃ | |
| Relative Humidity | 10% ~ 90% (Non-condensing) | |
| Atmospheric Pressure | 70kPa ~ 106kPa | |
| Protection Function | Protection Items | Overvoltage, Overcurrent, Short-circuit, Overtemperature, Lightning Protection |
Address: Room 229, Zhongzheng Fortune Building, No. 6093, Xinhe Community, Fuhai Sub-district, Bao'an District, Shenzhen
We are a professional supplier focusing on the R&D, sales, and export of communication power supplies and data center peripheral products. Our product portfolio covers mainstream brands including Vertiv (Emerson), Huawei, Eltek, ZTE, and Delta, involving embedded power systems, rectifier modules, power distribution cabinets, UPS, precision air conditioners, and supporting storage batteries. We also provide customized cabinet services to meet personalized project demands.
All products undergo strict performance testing, aging testing, and full-load testing before delivery to ensure reliable quality. We offer comprehensive after-sales support and sufficient spare parts within the warranty period, helping customers cut maintenance time and costs. Our products are exported to Southeast Asia, Africa, the Middle East, Europe, South Asia, and other regions, and have won wide recognition from global distributors and engineering clients.
A: It supports 220V and 380V AC input, with a wide working range from 80V to 300V AC, adapting to various complex power grid conditions.
A: The maximum total DC output current is 120A, with the total output power over 500W.
A: It is equipped with 6 DC load output channels and 2 dedicated battery input channels for flexible power distribution.
A: Yes. It adopts a Class C and Class D two-level lightning protection design to effectively resist surge damage.
A: The normal operating temperature is -40℃ to +55℃, which can adapt to harsh indoor and outdoor working environments.
A: Absolutely. It is specially designed for cabinet frames and widely used in all kinds of standard telecom cabinets.
A: Yes. We support sample testing, logo, and packaging customization to meet different project requirements.