The new-generation communication energy solution stands out for its simplicity.
Boasting intelligent and high-efficiency characteristics, it enables carriers to realize streamlined, end-to-end network deployment, network energy conservation, efficient operation and seamless evolution for future upgrades.
Highly integrated with power supply, temperature control, site monitoring and access systems, this solution delivers safe and reliable power supply and proper operating environment for core equipment.
| Product Model | Huahui-136868-A | Huahui-167676-A | Huahui-219595-A |
|---|---|---|---|
| External Dimensions (H×W×D) | 1300×680×680mm | 1600×760×760mm | 2100×950×950mm |
| Internal Dimensions (H×W×D) | 1100×620×620mm | 1400×660×660mm | 1800×820×820mm |
| Cabinet Material | Steel plate / Stainless steel | ||
| Maintenance Method | Front opening door / Front and rear opening door | ||
| Heat Dissipation | Air conditioner / Fan | ||
| Protection Grade | IP55 / IP65 | ||
| Equipment Rack | Equipment rack / Battery rack / Comprehensive rack | ||
| Installation Method | Ground installation | ||
| Brand | Huahui | ||
|
OVERVIEW |
|
|
Input |
|
|
Current (maximum) |
20 ADC |
|
Voltage DC (operating range) |
85 – 420 VDC |
|
Max input DC Voltage |
420 VDC |
|
DC Output |
|
|
Current (maximum) |
500 ADC |
|
Max voltage |
48 VDC |
|
Max power |
24 kW |
|
Battery Distribution |
|
|
Breaker positions up to |
8 |
|
Breaker rating up to |
250 A |
|
DC Load Distribution |
|
|
Breaker positions up to |
18 |
|
Breaker rating up to |
125 A |
|
LVLD |
Yes |
|
Other |
|
|
Operating temperature |
-40 – 70 °C |
|
Dimensions |
|
|
Dimensions WxHxD (mm) |
482 x 311 x 384 mm |
|
Dimensions WxHxD (inch) |
19 x 12.3 x 15.1 “ |
|
Weight |
12 kg |
|
OVERVIEW |
|
|
Input |
|
|
Current (maximum) |
20 ADC |
|
Voltage AC (operating range) |
85 – 300 VAC |
|
Voltage DC (operating range) |
85 – 420 VDC |
|
Max input AC Voltage |
300 VAC |
|
Max input DC Voltage |
420 VDC |
|
Mains configuration |
230/400VAC 3 phase (Y);230VAC 3 phase (Δ);230VAC Single phase |
|
DC Output |
|
|
Current (maximum) |
500 ADC |
|
Max voltage |
48 VDC |
|
Max power |
24 kW |
|
Battery Distribution |
|
|
Breaker positions up to |
8 |
|
Breaker rating up to |
250 A |
|
LVBD |
Yes |
|
DC Load Distribution |
|
|
Breaker positions up to |
18 |
|
Breaker rating up to |
125 A |
|
LVLD |
Yes |
|
Other |
|
|
Operating temperature |
-40 – 70 °C |
|
Dimensions |
|
|
Dimensions WxHxD (mm) |
482 x 384 x 356 mm |
|
Dimensions WxHxD (inch) |
19 x 15.1 x 17 “ |
|
Weight |
13 kg |
|
OVERVIEW |
|
|
Input |
|
|
Max input AC Voltage |
305 VAC |
|
Mains configuration |
230VAC Single phase;230VAC 3 phase (Δ);230/400VAC 3 phase (Y) |
|
DC Output |
|
|
Current (maximum) |
500 ADC |
|
Max voltage |
60 VDC |
|
Max power |
24 kW |
|
Battery Distribution |
|
|
Breaker positions up to |
8 |
|
Breaker rating up to |
250 A |
|
LVBD |
Yes |
|
DC Load Distribution |
|
|
Breaker positions up to |
20 |
|
Breaker rating up to |
125 A |
|
LVLD |
Yes |
|
Other |
|
|
Operating temperature |
-40 – 70 °C |
|
Mounting Type |
Rack 19” |
|
Dimensions |
|
|
Dimensions WxHxD (mm) |
482 x 380 x 311 mm |
|
Dimensions WxHxD (inch) |
19 x 14.96 x 12.3 “ |
|
Weight |
6 kg |
|
Design Standards |
|
|
Ingress Protection (IP) |
20 |
|
OVERVIEW |
|
|
Input |
|
|
Current (maximum) |
128 ADC |
|
Max input AC Voltage |
475 VAC |
|
Max input DC Voltage |
58 VDC |
|
Mains configuration |
230/400VAC 3 phase (Y) |
|
AC Output |
|
|
Max Output AC Voltage |
240 VAC |
|
Max power (kVA/kW) |
6 / 4.8 |
|
DC Output |
|
|
Max Power |
24000 W |
|
Current (maximum) |
500 ADC |
|
Max voltage |
58 VDC |
|
Max power |
24 kW |
|
Battery Distribution |
|
|
Breaker positions up to |
2 |
|
Breaker rating up to |
250 A |
|
LVBD |
Yes |
|
DC Load Distribution |
|
|
Breaker positions up to |
14 |
|
Breaker rating up to |
63 A |
|
LVLD |
Yes |
|
AC Load Distribution |
|
|
Number of breakers |
10 |
|
Breaker rating, up to |
10:00 AM |
|
Other |
|
|
Operating temperature |
-40 – 55 °C |
|
Dimensions |
|
|
Dimensions WxHxD (mm) |
482 x 311 x 432 mm |
|
Dimensions WxHxD (inch) |
18.98 x 12.24 x 17.01 “ |
|
Mounting dimensions |
19″ / 7U / 432 Width (Inch) / Height (U) / Depth (mm) |
|
Design Standards |
|
|
Ingress Protection (IP) |
20 |
|
OVERVIEW |
|
|
Input |
|
|
Current (maximum) |
128 ADC |
|
Max input AC Voltage |
475 VAC |
|
Max input DC Voltage |
58 VDC |
|
Mains configuration |
230/400VAC 3 phase (Y) |
|
AC Output |
|
|
Max Output AC Voltage |
240 VAC |
|
Max power (kVA/kW) |
6 / 4.8 |
|
DC Output |
|
|
Max Power |
16800 W |
|
Current (maximum) |
350 ADC |
|
Max voltage |
58 VDC |
|
Max power |
16.8 kW |
|
Battery Distribution |
|
|
Breaker positions up to |
2 |
|
Breaker rating up to |
200 A |
|
LVBD |
Yes |
|
DC Load Distribution |
|
|
Breaker positions up to |
14 |
|
Breaker rating up to |
63 A |
|
LVLD |
Yes |
|
AC Load Distribution |
|
|
Number of breakers |
10 |
|
Breaker rating, up to |
10:00 AM |
|
Other |
|
|
Operating temperature |
-40 – 55 °C |
|
Dimensions |
|
|
Dimensions WxHxD (mm) |
482 x 267 x 432 mm |
|
Dimensions WxHxD (inch) |
18.98 x 10.51 x 17.01 “ |
|
Mounting dimensions |
19″ / 6U / 432 Width (Inch) / Height (U) / Depth (mm) |
|
Design Standards |
|
|
Ingress Protection (IP) |
20 |
|
OVERVIEW |
|
|
Input |
|
|
Max input AC Voltage |
300 VAC |
|
Mains configuration |
230VAC Single phase;230VAC 3 phase (Δ);230/400VAC 3 phase (Y) |
|
DC Output |
|
|
Current (maximum) |
600 ADC |
|
Max voltage |
48 VDC |
|
Max power |
32 kW |
|
Battery Distribution |
|
|
Breaker positions up to |
6 |
|
Breaker rating up to |
250 A |
|
LVBD |
Yes |
|
DC Load Distribution |
|
|
Breaker positions up to |
18 |
|
Breaker rating up to |
125 A |
|
LVLD |
Yes |
|
Other |
|
|
Operating temperature |
-40 – 60 °C |
|
Storing temperature |
-40 – 85 °C |
|
Dimensions |
|
|
Dimensions WxHxD (mm) |
482 x 267 x 380 mm |
|
Dimensions WxHxD (inch) |
18,98 x 10,5 x 14,96 “ |
|
Weight |
5 kg |
|
OVERVIEW |
|
|
Input |
|
|
Current (maximum) |
64 ADC |
|
Max input AC Voltage |
240 VAC |
|
Max input DC Voltage |
58 VDC |
|
Mains configuration |
230VAC Single phase |
|
AC Output |
|
|
Max Output AC Voltage |
240 VAC |
|
Max power (kVA/kW) |
3 / 2.4 |
|
DC Output |
|
|
Voltage (adjustable range) |
43 – 58 VDC |
|
Current (maximum) |
50 ADC |
|
Max voltage |
58 VDC |
|
Max power |
2.4 kW |
|
DC Load Distribution |
|
|
LVLD |
No |
|
AC Load Distribution |
|
|
Number of breakers |
3 |
|
Breaker rating, up to |
10:00 AM |
|
Other |
|
|
Operating temperature |
-40 – 55 °C |
|
Dimensions |
|
|
Dimensions WxHxD (mm) |
482 x 44 x 395 mm |
|
Dimensions WxHxD (inch) |
18.98 x 1.73 x 15.55 “ |
|
Mounting dimensions |
19″ / 1U / 395 Width (Inch) / Height (U) / Depth (mm) |
|
Weight |
6 kg |
|
Design Standards |
|
|
Ingress Protection (IP) |
20 |
|
OVERVIEW |
|
|
Input |
|
|
Current (maximum) |
128 ADC |
|
Max input AC Voltage |
275 VAC |
|
Max input DC Voltage |
58 VDC |
|
Mains configuration |
230VAC Single phase |
|
AC Output |
|
|
Max Output AC Voltage |
240 VAC |
|
Max power (kVA/kW) |
6 / 4.8 |
|
DC Output |
|
|
Max Power |
4800 W |
|
Voltage (adjustable range) |
43 – 58 VDC |
|
Current (maximum) |
100 ADC |
|
Max voltage |
58 VDC |
|
Max power |
4.8 kW |
|
Other |
|
|
Cooling |
Single fan |
|
Operating temperature |
-40 – 55 °C |
|
Dimensions |
|
|
Dimensions WxHxD (mm) |
482 x 89 x 400 mm |
|
Dimensions WxHxD (inch) |
19 x 3.5 x 15.7 “ |
|
Mounting dimensions |
19″ / 2U / 400 Width (Inch) / Height (U) / Depth (mm) |
|
Weight |
9.4 kg |
|
Input |
|
|
Max input AC Voltage |
305 VAC |
|
Max input DC Voltage |
300 VDC |
|
Mains configuration |
230VAC Single phase;230VAC 3 phase (Δ);230/400VAC 3 phase (Y) |
|
DC Output |
|
|
Current (maximum) |
125 ADC |
|
Max voltage |
24 VDC |
|
Max power |
3 kW |
|
Battery Distribution |
|
|
Breaker positions up to |
1 |
|
Breaker rating up to |
100 A |
|
LVBD |
Yes |
|
DC Load Distribution |
|
|
Breaker positions up to |
10 |
|
Breaker rating up to |
20 A |
|
Other |
|
|
Operating temperature |
-40 – 65 °C |
|
Dimensions |
|
|
Dimensions WxHxD (mm) |
482.5 x 89 x 250 mm |
|
Dimensions WxHxD (inch) |
19 x 3.5 x 9.84 “ |
|
Weight |
7 kg |
|
Design Standards |
|
|
Ingress Protection (IP) |
20 |
|
OVERVIEW |
|
|
PRODUCT OVERVIEW |
|
|
Power Capacity |
18 – 28.8 kW |
|
Current Capacity |
40 – 600 A |
|
System Type |
System |
|
INPUT |
|
|
Input Voltage, Nominal |
Single phase: 120 VAC, 208 VAC to 240 VAC |
|
Input Voltage, Operational |
Rectifier: (Single Phase) 85 VAC to 300 VAC |
|
Input Connections |
Molex for AC cords or hardwiring |
|
Equipment Dimensions (H x W x D) |
Distribution cabinet: 4U x 19″ x 13.19″ or 8U x 23″ x 13.19″, Module shelf: 2U x (19″ or 23″) x 13.19″ |
|
Access |
Top or rear cabled with front and top access |
|
OUTPUT |
|
|
Output Voltage, Nominal |
-48V DC |
|
Output Voltage, Operational |
Rectifier: -42 VDC to -58 VDC |
|
Output Capacity |
Up to 600 amps at -48 VDC plus redundancy |
|
Peak Efficiency |
Rectifier: 96.5% |
|
Load Circuit Breakers / Fuses |
1-250 A E/M or E bullet nose breakers, 3-100 A TPS/TLS fuses, 18/100 A to 15 A GMT fuses |
|
PHYSICAL CHARACTERISTICS |
|
|
Battery Circuit Breakers / Fuses |
1A to 250 A E/M or E breakers, 50A to 2,00A GJ Breakers, 3A to 100A TPS/TLS fuses |
|
Options |
Optional Battery Trays, SM-Temp, BAU, Relay racks |
|
ENVIRONMETAL & STANDARD COMPLIANCE |
|
|
Control and Monitoring |
NCU with remote access via web browsers, TCP/IP & SNMP as standard |
|
Operating Temperature |
-40 °C to +65 °C ( 40 °F to +149 °F) |
|
Safety Compliance |
UL Listed (cUL) |
|
EMC Compliance |
Conforms to FCC rules Part 15, Subpart B, Class B; EN55022 Class B, radiated and conducted; GR-1089 Issue 4 |
|
PRODUCT OVERVIEW |
|
|
Power Capacity |
18 – 28.8 kW |
|
Current Capacity |
40 – 600 A |
|
System Type |
System |
|
INPUT |
|
|
Input Voltage, Nominal |
Single phase: 120 VAC, 208 VAC to 240 VAC |
|
Input Voltage, Operational |
Rectifier: (Single Phase) 85 VAC to 300 VAC |
|
Input Connections |
Molex for AC cords or hardwiring |
|
Equipment Dimensions (H x W x D) |
Distribution cabinet: 4U x 19″ x 13.19″ or 8U x 23″ x 13.19″, Module shelf: 2U x (19″ or 23″) x 13.19″ |
|
Access |
Top or rear cabled with front and top access |
|
OUTPUT |
|
|
Output Voltage, Nominal |
-48V DC |
|
Output Voltage, Operational |
Rectifier: -42 VDC to -58 VDC |
|
Output Capacity |
Up to 600 amps at -48 VDC plus redundancy |
|
Peak Efficiency |
Rectifier: 96.5% |
|
Load Circuit Breakers / Fuses |
1-250 A E/M or E bullet nose breakers, 3-100 A TPS/TLS fuses, 18/100 A to 15 A GMT fuses |
|
PHYSICAL CHARACTERISTICS |
|
|
Battery Circuit Breakers / Fuses |
1A to 250 A E/M or E breakers, 50A to 2,00A GJ Breakers, 3A to 100A TPS/TLS fuses |
|
Options |
Optional Battery Trays, SM-Temp, BAU, Relay racks |
|
ENVIRONMETAL & STANDARD COMPLIANCE |
|
|
Control and Monitoring |
NCU with remote access via web browsers, TCP/IP & SNMP as standard |
|
Operating Temperature |
-40 °C to +65 °C ( 40 °F to +149 °F) |
|
Safety Compliance |
UL Listed (cUL) |
|
EMC Compliance |
Conforms to FCC rules Part 15, Subpart B, Class B; EN55022 Class B, radiated and conducted; GR-1089 Issue 4 |
|
PRODUCT OVERVIEW |
|
|
Power Capacity |
24 kW |
|
Current Capacity |
500 A |
|
System Type |
Rack or cabinet mount |
|
INPUT |
|
|
Input Voltage, Nominal |
100 to 240 VAC |
|
Input Voltage, Operational |
120/208/240 VAC, single phase (operational) |
|
Input Connections |
Terminal block (up to 6 AWG) for individual rectifier feed |
|
Access |
Front and rear for installation, Front for operation and maintenance |
|
OUTPUT |
|
|
Output Voltage, Nominal |
-48 VDC |
|
Output Capacity |
350 A @ +65 °C; 500 A @ +40 °C |
|
Load Circuit Breakers / Fuses |
(21) (6 on Load 1 bus, 6 on Load 2 bus, 9 on Priority bus) |
|
PHYSICAL CHARACTERISTICS |
|
|
Weight |
19.1 to 24.5 kg |
|
Height |
6-8U (266 to 347 mm) |
|
Width |
483 mm |
|
Depth |
395 to 420 mm |
|
ENVIRONMETAL & STANDARD COMPLIANCE |
|
|
Operating Temperature |
-40°C to +65°C (-40°F to +149°F) |
|
Safety Compliance |
UL 62368 Recognized |
|
PRODUCT OVERVIEW |
|
|
Power Capacity |
1000 W |
|
Current Capacity |
20.8A |
|
INPUT |
|
|
Input Voltage, Nominal |
85 VAC to 300 VAC operating range |
|
Equipment Dimensions (H x W x D) |
9.8 x 3.4 x 10.9 (inches) / 226 x 86 x 277 (mm) |
|
OUTPUT |
|
|
Output Voltage, Nominal |
-42.0 VDC to -58.0 VDC |
|
PHYSICAL CHARACTERISTICS |
|
|
Weight |
2.7 kgs |
|
Height |
226 mm |
|
Width |
86 mm |
|
Depth |
277 mm |
|
ENVIRONMETAL & STANDARD COMPLIANCE |
|
|
PRODUCT OVERVIEW |
|
|
Power Capacity |
3 kW |
|
Current Capacity |
48 A |
|
System Type |
Subrack |
|
INPUT |
|
|
Input Voltage, Nominal |
120, 208, 240 VAC |
|
OUTPUT |
|
|
Output Voltage, Nominal |
-48 VDC |
|
PHYSICAL CHARACTERISTICS |
|
|
Weight |
5 |
|
Height |
43.6 |
|
Width |
482 |
|
Depth |
279 |
|
ENVIRONMETAL & STANDARD COMPLIANCE |
|
|
Operating Temperature |
-40 °C to 70 °C (-40 °F to 158 °F) |
|
Safety Compliance |
UL 1801 Recognized |
|
EMC Compliance |
Conforms to FCC rules Part 15, Subpart B, Class B and EN55022 Class B, radiated and conducted |
|
PRODUCT OVERVIEW |
|
|
Power Capacity |
1 GW |
|
Current Capacity |
20,000 A |
|
System Type |
Systems |
|
INPUT |
|
|
Input Voltage, Nominal |
480 VAC, three phase |
|
Input Voltage, Operational |
304 VAC to 530 VAC |
|
Equipment Dimensions (H x W x D) |
Power bay (H x W x D): 7′ x 24.375″ x 30″, Distribution bay (H x W x D): 7′ x 30″ x 30″ |
|
Access |
Front and rear |
|
OUTPUT |
|
|
Output Voltage, Nominal |
48 VDC |
|
Output Voltage, Operational |
42.0 VDC to 58.0 VDC |
|
Output Capacity |
5800 W rectifier |
|
Peak Efficiency |
93% |
|
Load Circuit Breakers / Fuses |
TPS/TLS, TPL Fuses or GJ/218-Style breakers |
|
ENVIRONMETAL & STANDARD COMPLIANCE |
|
|
Control and Monitoring |
MCA controller with remote control via Ethernet (Telnet, web page, SNMP and TL1) |
|
Operating Temperature |
-32 °F to 104 °F (-0 °C to 40 °C) |
|
Safety Compliance |
UL Listed 1801, cUL, NEBS Level 3 |
|
EMC Compliance |
Comfors to FCC rules Part 15, Subpart B, Class A and EN55022 Class A |
|
PRODUCT OVERVIEW |
|
|
Power Capacity |
1 MW |
|
Current Capacity |
20,000 A |
|
System Type |
Power Bay |
|
INPUT |
|
|
Input Voltage, Nominal |
208 or 480 VAC, 3-phase |
|
Input Voltage, Operational |
408-528 VAC to 176-264 VAC |
|
Equipment Dimensions (H x W x D) |
Combo Bay List 101 and List 111 93.5″x24″x30″,830 lbs., Combo Bay List 102 and List 112 84″x24″x 30″, 830 lbs., AC Distribution Bay (PDSC): 84″ x 1 |
|
Access |
Front and rear |
|
OUTPUT |
|
|
Output Voltage, Nominal |
48 VDC |
|
Output Voltage, Operational |
42.0 VDC to 58.0 VDC |
|
Output Capacity |
12,000 W rectifier |
|
Peak Efficiency |
96.1% (480 VAC), 95.7% (208 VAC) |
|
Load Circuit Breakers / Fuses |
TPS/TLS, TPL Fuses or GJ/218-Style breakers |
|
ENVIRONMETAL & STANDARD COMPLIANCE |
|
|
Control and Monitoring |
NCU controller |
|
Operating Temperature |
0 °C to +40 °C (+32 °F to +104 °F) |
|
Safety Compliance |
UL Listed (UL1801), CSA 22.2 (No. 225), c UL, NEBS Level 3 |
|
INPUT |
|
|
Input Voltage, Nominal |
208 VAC to 277/480 VAC |
|
Input Voltage, Operational |
176 VAC to 305/528 VAC |
|
Input Connections |
Terminal Blocks or Line Cords |
|
Equipment Dimensions (H x W x D) |
D Cabinet:12.2″ (7RU) to 33.25″ (19RU) x 23″ x 20.1″, R Shelves:1.7″ (1RU) or 5.2″ (3RU) x 23″ x 20.1″ |
|
Access |
Front for installation, operation and maintenance, Rear for multi-bay, rectifier shelf or battery tray expansion |
|
OUTPUT |
|
|
Output Voltage, Nominal |
-48 VDC |
|
Output Voltage, Operational |
42.0 VDC to 58.0 VDC |
|
Output Capacity |
Rectifier: 3500 W or 2000 W, Converter: 1500 W, Shelf: 21 kW or 12 kW @ 48 VDC, 4.5 kW @ 24 VDC, System: 200 kW @ 48 VDC, 12.5 kW @ 24 VDC |
|
Peak Efficiency |
96.50% |
|
Load Circuit Breakers / Fuses |
Up to (104) Bullet CBs, 1 to 300 A, Up to (24) GJ/218 CBs, 100 to 800 A, Up to (16) TPH Fuses, 70 to 600 A, Up to (16) TBL-B Fuses, 70 to 250 A |
|
PHYSICAL CHARACTERISTICS |
|
|
Battery Circuit Breakers / Fuses |
Up to (24) Bullet CBs, 1 to 300 A, Up to (4) GJ/218 CBs, 100 to 800 A, Up to (4) TPH Fuses, 70 to 600 A /up to 200A CB Disconnect mounted on each batt |
|
Options |
Low Voltage Load Disconnect, Low Voltage Batttery Disconnect, Battery Shunt, Battery Trays – Pre- cabled, Bulk Output Panel, Up to (68) Temp Sensors |
|
Weight |
90.9 to 295.5 kg |
|
Height |
2134 mm |
|
Width |
584.2 to 711.2 mm |
|
Depth |
510.5 to 711.2 mm |
|
ENVIRONMETAL & STANDARD COMPLIANCE |
|
|
Control and Monitoring |
Dual Ethernet, Embedded web pages, SNMP, Modbus, Battery Management, Programmable Relay Outputs and Binary Inputs, Energy Management |
|
Operating Temperature |
-40 °C to +40 °C (-40 °F to +104 °F) |
|
Safety Compliance |
UL 1801 Listed (“c UL”), NEBS Level 3 |
|
EMC Compliance |
FCC Class B |
|
PRODUCT OVERVIEW |
|
|
Power Capacity |
240 kW (8 load) or 180 kW (6 load) |
|
Current Capacity |
4800 A (8 load) or 3600 A (6 load) |
|
System Type |
Distribution Bay |
|
INPUT |
|
|
Input Voltage, Nominal |
48 VDC |
|
Input Voltage, Operational |
42.0 VDC to 58.0 VDC |
|
Access |
Top and bottom |
|
OUTPUT |
|
|
Output Voltage, Nominal |
48 VDC |
|
Output Voltage, Operational |
42.0 VDC to 58.0 VDC |
|
Load Circuit Breakers / Fuses |
TPS/TLS, TPL, GMT Fuses or Bullet Circuit Breakers |
|
PHYSICAL CHARACTERISTICS |
|
|
Weight |
73 – 193 |
|
Height |
2134 |
|
Width |
660 – 762 |
|
Depth |
406 -609 |
|
ENVIRONMETAL & STANDARD COMPLIANCE |
|
|
Control and Monitoring |
Digital metering with remote control over Modbus or SNMP |
|
Operating Temperature |
0 °C to +40 °C (+32 °F to +104 °F) |
|
Safety Compliance |
NEBS level 3 compliance, meets or exceeds all relevant GR1089, GR63, UL, cUL specifications |
|
PRODUCT OVERVIEW |
|
|
Power Capacity |
1 GW |
|
Current Capacity |
20,000 A |
|
System Type |
Power Bay |
|
INPUT |
|
|
Input Voltage, Nominal |
208 VAC to 480 VAC; three phase |
|
Input Voltage, Operational |
408-528 VAC to 176-264 VAC |
|
Equipment Dimensions (H x W x D) |
Combo Bay List 1 and List 11 93.5″ x 24″ x 30″, 830 lbs., Combo Bay List 2 and List 12 84″ x 24″ x 30″, 830 lbs., AC Distribution Bay (PDSC): 84″ x 1 |
|
Access |
Front and rear |
|
OUTPUT |
|
|
Output Voltage, Nominal |
48 VDC |
|
Output Voltage, Operational |
42.0 VDC to 58.0 VDC |
|
Output Capacity |
12,000 W rectifier |
|
Peak Efficiency |
96.1% (480 VAC), 95.7% (208 VAC) |
|
Load Circuit Breakers / Fuses |
TPS/TLS, TPL Fuses or GJ/218-Style breakers |
|
ENVIRONMETAL & STANDARD COMPLIANCE |
|
|
Control and Monitoring |
MAC controller with optional monitor LMS1000 |
|
Operating Temperature |
0 °C to +40 °C (+32 °F to +104 °F) |
|
Safety Compliance |
UL Listed (UL1801), CSA 22.2 (No. 225), c UL, NEBS Level 3 |