Products
PRODUCTS DETAILS
Home > Products >
Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems

Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems

Detail Information
Product Description
Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems

Our outdoor communication cabinets are designed for 4G/5G base stations with standard size 800×800×1800mm, fully customizable to meet your specific requirements.

We offer comprehensive Outdoor Communication Cabinet solutions with custom manufacturing capabilities. Contact us via email or WhatsApp for personalized assistance and quotations.

Product Overview
This series features fully enclosed heat exchanger outdoor cabinets with sealed design and efficient thermal management. Engineered to withstand extreme environmental conditions including high temperatures, severe cold, desert climates, and coastal areas. These cabinets support rapid outdoor deployment of high-capacity copper cables and OLT equipment, with proven reliability recognized by global operators across 100+ countries.

The new-generation communication energy solution stands out for its simplicity.
Boasting intelligent and high-efficiency characteristics, it enables carriers to realize streamlined, end-to-end network deployment, network energy conservation, efficient operation and seamless evolution for future upgrades.
Highly integrated with power supply, temperature control, site monitoring and access systems, this solution delivers safe and reliable power supply and proper operating environment for core equipment.



Technical Specifications
Product Model Huahui-136868-A Huahui-167676-A Huahui-219595-A
External Dimensions (H×W×D) 1300×680×680mm 1600×760×760mm 2100×950×950mm
Internal Dimensions (H×W×D) 1100×620×620mm 1400×660×660mm 1800×820×820mm
Cabinet Material Steel plate / Stainless steel
Maintenance Method Front opening door / Front and rear opening door
Heat Dissipation Air conditioner / Fan
Protection Grade IP55 / IP65
Equipment Rack Equipment rack / Battery rack / Comprehensive rack
Installation Method Ground installation
Brand Huahui

Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems

OVERVIEW


Input


Current (maximum)

20 ADC

Voltage DC (operating range)

85 420 VDC

Max input DC Voltage

420 VDC

DC Output


Current (maximum)

500 ADC

Max voltage

48 VDC

Max power

24 kW

Battery Distribution


Breaker positions up to

8

Breaker rating up to

250 A

DC Load Distribution


Breaker positions up to

18

Breaker rating up to

125 A

LVLD

Yes

Other


Operating temperature

-40 70 °C

Dimensions


Dimensions WxHxD (mm)

482 x 311 x 384 mm

Dimensions WxHxD (inch)

19 x 12.3 x 15.1

Weight

12 kg


Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems

OVERVIEW


Input


Current (maximum)

20 ADC

Voltage AC (operating range)

85 300 VAC

Voltage DC (operating range)

85 420 VDC

Max input AC Voltage

300 VAC

Max input DC Voltage

420 VDC

Mains configuration

230/400VAC 3 phase (Y);230VAC 3

phase (Δ);230VAC Single phase

DC Output


Current (maximum)

500 ADC

Max voltage

48 VDC

Max power

24 kW

Battery Distribution


Breaker positions up to

8

Breaker rating up to

250 A

LVBD

Yes

DC Load Distribution


Breaker positions up to

18

Breaker rating up to

125 A

LVLD

Yes

Other


Operating temperature

-40 70 °C

Dimensions


Dimensions WxHxD (mm)

482 x 384 x 356 mm

Dimensions WxHxD (inch)

19 x 15.1 x 17

Weight

13 kg

Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems

OVERVIEW


Input


Max input AC Voltage

305 VAC

Mains configuration

230VAC Single phase;230VAC 3

phase (Δ);230/400VAC 3 phase (Y)

DC Output


Current (maximum)

500 ADC

Max voltage

60 VDC

Max power

24 kW

Battery Distribution


Breaker positions up to

8

Breaker rating up to

250 A

LVBD

Yes

DC Load Distribution


Breaker positions up to

20

Breaker rating up to

125 A

LVLD

Yes

Other


Operating temperature

-40 70 °C

Mounting Type

Rack 19

Dimensions


Dimensions WxHxD (mm)

482 x 380 x 311 mm

Dimensions WxHxD (inch)

19 x 14.96 x 12.3

Weight

6 kg

Design Standards


Ingress Protection (IP)

20

Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems

OVERVIEW


Input


Current (maximum)

128 ADC

Max input AC Voltage

475 VAC

Max input DC Voltage

58 VDC

Mains configuration

230/400VAC  3 phase (Y)

AC Output


Max Output AC Voltage

240 VAC

Max power (kVA/kW)

6 / 4.8

DC Output


Max Power

24000 W

Current (maximum)

500 ADC

Max voltage

58 VDC

Max power

24 kW

Battery Distribution


Breaker positions up to

2

Breaker rating up to

250 A

LVBD

Yes

DC Load Distribution


Breaker positions up to

14

Breaker rating up to

63 A

LVLD

Yes

AC Load Distribution


Number of breakers

10

Breaker rating, up to

10:00 AM

Other


Operating temperature

-40 55 °C

Dimensions


Dimensions WxHxD (mm)

482 x 311 x 432 mm

Dimensions WxHxD (inch)

18.98  x 12.24  x 17.01  

Mounting dimensions

19 / 7U / 432  Width (Inch) / Height (U) /

Depth (mm)

Design Standards


Ingress Protection (IP)

20

Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems

OVERVIEW


Input


Current (maximum)

128 ADC

Max input AC Voltage

475 VAC

Max input DC Voltage

58 VDC

Mains configuration

230/400VAC  3 phase (Y)

AC Output


Max Output AC Voltage

240 VAC

Max power (kVA/kW)

6 / 4.8

DC Output


Max Power

16800 W

Current (maximum)

350 ADC

Max voltage

58 VDC

Max power

16.8 kW

Battery Distribution


Breaker positions up to

2

Breaker rating up to

200 A

LVBD

Yes

DC Load Distribution


Breaker positions up to

14

Breaker rating up to

63 A

LVLD

Yes

AC Load Distribution


Number of breakers

10

Breaker rating, up to

10:00 AM

Other


Operating temperature

-40 55 °C

Dimensions


Dimensions WxHxD (mm)

482 x 267 x 432 mm

Dimensions WxHxD (inch)

18.98  x 10.51  x 17.01  

Mounting dimensions

19 / 6U / 432  Width (Inch) / Height (U) /

Depth (mm)

Design Standards


Ingress Protection (IP)

20

Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems

OVERVIEW


Input


Max input AC Voltage

300 VAC

Mains configuration

230VAC Single phase;230VAC 3

phase (Δ);230/400VAC 3 phase (Y)

DC Output


Current (maximum)

600 ADC

Max voltage

48 VDC

Max power

32 kW

Battery Distribution


Breaker positions up to

6

Breaker rating up to

250 A

LVBD

Yes

DC Load Distribution


Breaker positions up to

18

Breaker rating up to

125 A

LVLD

Yes

Other


Operating temperature

-40 60 °C

Storing temperature

-40 85 °C

Dimensions


Dimensions WxHxD (mm)

482 x 267 x 380 mm

Dimensions WxHxD (inch)

18,98 x 10,5 x 14,96

Weight

5 kg

Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems

OVERVIEW


Input


Current (maximum)

64 ADC

Max input AC Voltage

240 VAC

Max input DC Voltage

58 VDC

Mains configuration

230VAC Single phase

AC Output


Max Output AC Voltage

240 VAC

Max power (kVA/kW)

3 / 2.4

DC Output


Voltage (adjustable range)

43 58 VDC

Current (maximum)

50 ADC

Max voltage

58 VDC

Max power

2.4 kW

DC Load Distribution


LVLD

No

AC Load Distribution


Number of breakers

3

Breaker rating, up to

10:00 AM

Other


Operating temperature

-40 55 °C

Dimensions


Dimensions WxHxD (mm)

482 x 44 x 395 mm

Dimensions WxHxD (inch)

18.98 x 1.73 x 15.55

Mounting dimensions

19″ / 1U / 395 Width (Inch) / Height (U) /

Depth (mm)

Weight

6 kg

Design Standards


Ingress Protection (IP)

20

Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems

OVERVIEW


Input


Current (maximum)

128 ADC

Max input AC Voltage

275 VAC

Max input DC Voltage

58 VDC

Mains configuration

230VAC Single phase

AC Output


Max Output AC Voltage

240 VAC

Max power (kVA/kW)

6 / 4.8

DC Output


Max Power

4800 W

Voltage (adjustable range)

43 58 VDC

Current (maximum)

100 ADC

Max voltage

58 VDC

Max power

4.8 kW

Other


Cooling

Single fan

Operating temperature

-40 55 °C

Dimensions


Dimensions WxHxD (mm)

482 x 89 x 400 mm

Dimensions WxHxD (inch)

19 x 3.5 x 15.7

Mounting dimensions

19 / 2U / 400 Width (Inch) / Height (U)

/ Depth (mm)

Weight

9.4 kg

Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems

Input


Max input AC Voltage

305 VAC

Max input DC Voltage

300 VDC

Mains configuration

230VAC Single phase;230VAC 3 phase

(Δ);230/400VAC 3 phase (Y)

DC Output


Current (maximum)

125 ADC

Max voltage

24 VDC

Max power

3 kW

Battery Distribution


Breaker positions up to

1

Breaker rating up to

100 A

LVBD

Yes

DC Load Distribution


Breaker positions up to

10

Breaker rating up to

20 A

Other


Operating temperature

-40 65 °C

Dimensions


Dimensions WxHxD (mm)

482.5 x 89 x 250 mm

Dimensions WxHxD (inch)

19 x 3.5 x 9.84

Weight

7 kg

Design Standards


Ingress Protection (IP)

20

Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systemsRobust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systemsRobust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems

OVERVIEW


PRODUCT OVERVIEW


Power Capacity

18 28.8 kW

Current Capacity

40 600 A

System Type

System

INPUT


Input Voltage, Nominal

Single phase: 120 VAC, 208 VAC to 240 VAC

Input Voltage, Operational

Rectifier: (Single Phase) 85 VAC to 300 VAC

Input Connections

Molex for AC cords or hardwiring

Equipment Dimensions (H x W x D)

Distribution  cabinet: 4U x 19 x 13.19 or 8U x 23 x 13.19,  Module shelf: 2U x (19 or 23) x 13.19

Access

Top or rear cabled with front and top access

OUTPUT


Output Voltage, Nominal

-48V DC

Output Voltage, Operational

Rectifier: -42 VDC to -58 VDC

Output Capacity

Up to 600 amps at -48 VDC plus redundancy

Peak Efficiency

Rectifier: 96.5%

Load Circuit Breakers / Fuses

1-250 A E/M or E bullet nose breakers, 3-100 A TPS/TLS fuses, 18/100 A to 15 A GMT fuses

PHYSICAL CHARACTERISTICS


Battery Circuit Breakers / Fuses

1A to 250 A E/M or E breakers, 50A to 2,00A GJ Breakers,

3A to 100A TPS/TLS fuses

Options

Optional Battery Trays, SM-Temp, BAU, Relay racks

ENVIRONMETAL & STANDARD COMPLIANCE


Control and Monitoring

NCU with remote access via web browsers, TCP/IP &

SNMP as standard

Operating Temperature

-40 °C to +65 °C ( 40 °F to +149 °F)

Safety Compliance

UL Listed (cUL)

EMC Compliance

Conforms to FCC rules Part 15, Subpart B, Class B; EN55022 Class B, radiated and conducted; GR-1089 Issue 4

Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems

PRODUCT OVERVIEW


Power Capacity

18 28.8 kW

Current Capacity

40 600 A

System Type

System

INPUT


Input Voltage, Nominal

Single phase: 120 VAC, 208 VAC to 240 VAC

Input Voltage, Operational

Rectifier: (Single Phase) 85 VAC to 300 VAC

Input Connections

Molex for AC cords or hardwiring

Equipment Dimensions (H x W x D)

Distribution  cabinet: 4U x 19 x 13.19 or 8U x 23 x 13.19,

Module shelf: 2U x (19 or 23) x 13.19

Access

Top or rear cabled with front and top access

OUTPUT


Output Voltage, Nominal

-48V DC

Output Voltage, Operational

Rectifier: -42 VDC to -58 VDC

Output Capacity

Up to 600 amps at -48 VDC plus redundancy

Peak Efficiency

Rectifier: 96.5%

Load Circuit Breakers / Fuses

1-250 A E/M or E bullet nose breakers, 3-100 A TPS/TLS fuses, 18/100 A to 15 A GMT fuses

PHYSICAL CHARACTERISTICS


Battery Circuit Breakers / Fuses

1A to 250 A E/M or E breakers, 50A to 2,00A GJ Breakers, 3A to 100A TPS/TLS fuses

Options

Optional Battery Trays, SM-Temp, BAU, Relay racks

ENVIRONMETAL & STANDARD COMPLIANCE


Control and Monitoring

NCU with remote access via web browsers, TCP/IP & SNMP as standard

Operating Temperature

-40 °C to +65 °C ( 40 °F to +149 °F)

Safety Compliance

UL Listed (cUL)

EMC Compliance

Conforms to FCC rules Part 15, Subpart B, Class B; EN55022 Class B, radiated and conducted; GR-1089 Issue 4

Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems

PRODUCT OVERVIEW


Power Capacity

24 kW

Current Capacity

500 A

System Type

Rack or cabinet mount

INPUT


Input Voltage, Nominal

100 to 240 VAC

Input Voltage, Operational

120/208/240 VAC, single phase

(operational)

Input Connections

Terminal block (up to 6 AWG) for

individual rectifier feed

Access

Front and rear for installation, Front for operation and maintenance

OUTPUT


Output Voltage, Nominal

-48 VDC

Output Capacity

350 A @ +65 °C; 500 A @ +40 °C

Load Circuit Breakers / Fuses

(21) (6 on Load 1 bus, 6 on Load 2 bus, 9 on Priority bus)

PHYSICAL CHARACTERISTICS


Weight

19.1 to 24.5 kg

Height

6-8U (266 to 347 mm)

Width

483 mm

Depth

395 to 420 mm

ENVIRONMETAL & STANDARD COMPLIANCE


Operating Temperature

-40°C to +65°C (-40°F to +149°F)

Safety Compliance

UL 62368 Recognized

Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems

PRODUCT OVERVIEW


Power Capacity

1000 W

Current Capacity

20.8A

INPUT


Input Voltage, Nominal

85 VAC to 300 VAC operating range

Equipment Dimensions (H x W x D)

9.8 x 3.4 x 10.9 (inches) / 226 x 86 x

277 (mm)

OUTPUT


Output Voltage, Nominal

-42.0 VDC to -58.0 VDC

PHYSICAL CHARACTERISTICS


Weight

2.7 kgs

Height

226 mm

Width

86 mm

Depth

277 mm

ENVIRONMETAL & STANDARD COMPLIANCE


Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems

PRODUCT OVERVIEW


Power Capacity

3 kW

Current Capacity

48 A

System Type

Subrack

INPUT


Input Voltage, Nominal

120, 208, 240 VAC

OUTPUT


Output Voltage, Nominal

-48 VDC

PHYSICAL CHARACTERISTICS


Weight

5

Height

43.6

Width

482

Depth

279

ENVIRONMETAL & STANDARD COMPLIANCE


Operating Temperature

-40 °C to 70 °C (-40 °F to 158 °F)

Safety Compliance

UL 1801 Recognized

EMC Compliance

Conforms to FCC rules Part 15, Subpart B, Class B and EN55022 Class B, radiated and conducted

Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems

PRODUCT OVERVIEW


Power Capacity

1 GW

Current Capacity

20,000 A

System Type

Systems

INPUT


Input Voltage, Nominal

480 VAC, three phase

Input Voltage, Operational

304 VAC to 530 VAC

Equipment Dimensions (H x W x D)

Power bay (H x W x D): 7 x 24.375 x 30, Distribution bay (H x W x D): 7 x 30 x 30

Access

Front and rear

OUTPUT


Output Voltage, Nominal

48 VDC

Output Voltage, Operational

42.0 VDC to 58.0 VDC

Output Capacity

5800 W rectifier

Peak Efficiency

93%

Load Circuit Breakers / Fuses

TPS/TLS, TPL Fuses or GJ/218-Style breakers

ENVIRONMETAL & STANDARD COMPLIANCE


Control and Monitoring

MCA controller with remote control via Ethernet (Telnet, web page, SNMP and TL1)

Operating Temperature

-32 °F to 104 °F (-0 °C to 40 °C)

Safety Compliance

UL Listed 1801, cUL, NEBS Level 3

EMC Compliance

Comfors to FCC rules Part 15, Subpart B, Class

A and EN55022 Class A

Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems

PRODUCT OVERVIEW


Power Capacity

1 MW

Current Capacity

20,000 A

System Type

Power Bay

INPUT


Input Voltage, Nominal

208 or 480 VAC, 3-phase

Input Voltage, Operational

408-528 VAC to 176-264 VAC

Equipment Dimensions (H x W x D)

Combo Bay List 101 and List 111 93.5x24x30,830 lbs., Combo Bay List 102 and List 112 84x24x 30, 830 lbs., AC Distribution Bay (PDSC): 84 x 1

Access

Front and rear

OUTPUT


Output Voltage, Nominal

48 VDC

Output Voltage, Operational

42.0 VDC to 58.0 VDC

Output Capacity

12,000 W rectifier

Peak Efficiency

96.1% (480 VAC), 95.7% (208 VAC)

Load Circuit Breakers / Fuses

TPS/TLS, TPL Fuses or GJ/218-Style breakers

ENVIRONMETAL & STANDARD COMPLIANCE


Control and Monitoring

NCU controller

Operating Temperature

0 °C to +40 °C (+32 °F to +104 °F)

Safety Compliance

UL Listed (UL1801), CSA 22.2 (No. 225), c UL, NEBS

Level 3

Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems

INPUT


Input Voltage, Nominal

208 VAC to 277/480  VAC

Input Voltage, Operational

176 VAC to 305/528  VAC

Input Connections

Terminal Blocks or Line Cords

Equipment Dimensions (H x W x D)

D Cabinet:12.2 (7RU)  to 33.25 (19RU)  x 23 x 20.1″,  R Shelves:1.7 (1RU)  or 5.2 (3RU) x 23 x 20.1

Access

Front for installation, operation and maintenance, Rear for multi-bay, rectifier shelf or battery tray expansion

OUTPUT


Output Voltage, Nominal

-48 VDC

Output Voltage, Operational

42.0 VDC to 58.0 VDC

Output Capacity

Rectifier: 3500 W or 2000 W, Converter: 1500 W, Shelf: 21 kW or 12 kW @ 48 VDC, 4.5 kW @ 24 VDC,

System: 200 kW @ 48 VDC, 12.5 kW @ 24 VDC

Peak Efficiency

96.50%

Load Circuit Breakers / Fuses

Up to (104) Bullet CBs, 1 to 300 A, Up to (24) GJ/218 CBs, 100 to 800 A, Up to (16) TPH Fuses, 70 to 600 A, Up to (16) TBL-B Fuses, 70 to 250 A

PHYSICAL CHARACTERISTICS


Battery Circuit Breakers / Fuses

Up to (24) Bullet CBs, 1 to 300 A, Up to (4) GJ/218 CBs, 100 to 800 A, Up to (4) TPH Fuses, 70 to 600 A

/up to 200A CB Disconnect mounted on each batt

Options

Low Voltage Load Disconnect, Low Voltage Batttery Disconnect, Battery Shunt, Battery Trays Pre- cabled, Bulk Output Panel, Up to (68) Temp Sensors

Weight

90.9 to 295.5 kg

Height

2134 mm

Width

584.2 to 711.2 mm

Depth

510.5 to 711.2 mm

ENVIRONMETAL & STANDARD COMPLIANCE


Control and Monitoring

Dual Ethernet, Embedded web pages, SNMP, Modbus, Battery Management, Programmable Relay Outputs and Binary Inputs, Energy Management

Operating Temperature

-40 °C to +40 °C (-40 °F to +104 °F)

Safety Compliance

UL 1801  Listed (“c UL”), NEBS Level 3

EMC Compliance

FCC Class B

Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems

PRODUCT OVERVIEW


Power Capacity

240 kW (8 load) or 180 kW (6 load)

Current Capacity

4800 A (8 load) or 3600 A (6 load)

System Type

Distribution Bay

INPUT


Input Voltage, Nominal

48 VDC

Input Voltage, Operational

42.0 VDC to 58.0 VDC

Access

Top and bottom

OUTPUT


Output Voltage, Nominal

48 VDC

Output Voltage, Operational

42.0 VDC to 58.0 VDC

Load Circuit Breakers / Fuses

TPS/TLS, TPL, GMT Fuses or Bullet Circuit

Breakers

PHYSICAL CHARACTERISTICS


Weight

73 193

Height

2134

Width

660 762

Depth

406 -609

ENVIRONMETAL & STANDARD COMPLIANCE


Control and Monitoring

Digital metering with remote control over Modbus or SNMP

Operating Temperature

0 °C to +40 °C (+32 °F to +104 °F)

Safety Compliance

NEBS level 3 compliance, meets or exceeds all

relevant GR1089, GR63, UL, cUL specifications

Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems

PRODUCT OVERVIEW


Power Capacity

1 GW

Current Capacity

20,000 A

System Type

Power Bay

INPUT


Input Voltage, Nominal

208 VAC to 480 VAC; three phase

Input Voltage, Operational

408-528 VAC to 176-264 VAC

Equipment Dimensions (H x W x D)

Combo Bay List 1 and List 11 93.5 x 24 x 30, 830 lbs., Combo Bay List 2 and List 12 84 x 24 x 30, 830 lbs., AC Distribution Bay (PDSC): 84 x 1

Access

Front and rear

OUTPUT


Output Voltage, Nominal

48 VDC

Output Voltage, Operational

42.0 VDC to 58.0 VDC

Output Capacity

12,000 W rectifier

Peak Efficiency

96.1% (480 VAC), 95.7% (208 VAC)

Load Circuit Breakers / Fuses

TPS/TLS, TPL Fuses or GJ/218-Style breakers

ENVIRONMETAL & STANDARD COMPLIANCE


Control and Monitoring

MAC controller with optional monitor LMS1000

Operating Temperature

0 °C to +40 °C (+32 °F to +104 °F)

Safety Compliance

UL Listed (UL1801), CSA 22.2 (No. 225), c UL,

NEBS Level 3

Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systemsRobust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems
Robust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systemsRobust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systemsRobust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systemsRobust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systemsRobust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systemsRobust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systemsRobust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systemsRobust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systemsRobust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systemsRobust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systemsRobust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systemsRobust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systemsRobust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systemsRobust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systemsRobust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systemsRobust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systemsRobust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systemsRobust Outdoor Power Cabinet designed for harsh environments providing protection and cooling for telecommunication systems

Product Attributes
  • Source Category: In Stock
  • Time to Market: 2022
  • Origin: Guangdong, China
  • Cabinet Capacity: Multiple sizes available
  • Fastest Shipping: 10 days
  • Surface Treatment: Spray coating
Power & Support
  • UPS Built-in Battery: 9AH/12V or above
  • UPS External Battery: 100AH/12V or above
  • UPS Rated Load: 1601-2400W
  • Accessories: Air-conditioning included
  • After-sales: One year warranty
  • Packing: Wooden frame with protective materials
Key Features & Benefits
High Reliability
  • Excellent EMC performance and external damage resistance
  • IP55 protection rating for harsh outdoor environments
  • Dual heat dissipation units with dual fan design
  • Sealed construction prevents dust and corrosive gas ingress
  • 60KA lightning protection module with MDF security unit
Environmental Performance
  • Automatic fan speed regulation for energy efficiency
  • Low noise operation suitable for residential areas
  • Reduced power consumption
Enhanced Security
  • Built-in hinges prevent prying and theft
  • Internal mounting holes for anti-theft protection
  • HW-2801 door lock configuration
  • Support for electronic locks, alarms, and reinforced barriers
  • Separate equipment and MDF compartments
Integrated Solutions
  • Complete cabinet with main equipment, power supply, and monitoring
  • Ready for installation without secondary integration
  • Quick deployment capabilities
Maintenance Efficiency
  • Pre-maintenance support for equipment compartment
  • Front wiring operation for MDF
  • Optional portable lighting for night operations
  • AC power maintenance sockets for on-site tools
Comprehensive Monitoring
  • Real-time environmental monitoring (temperature, humidity, access control)
  • Power supply equipment and battery monitoring
  • Component monitoring for patch panels and fans
  • Remote alarm capabilities
Professional Customization Services
We provide custom cabinet solutions in various sizes and styles based on your specifications and drawings.
Complete Outdoor Cabinet Solutions
  • Intelligent constant temperature control systems
  • Smart power supply management
  • Advanced monitoring capabilities
  • Superior rainproof and dustproof performance
  • Comprehensive anti-theft and anti-corrosion measures
  • Full customization support for unique requirements
sitemap |  Privacy Policy | China Good Quality Energy Storage Cabinet Supplier. Copyright © 2025-2026 Shenzhen Zhongchen Huahui Technology Co., Ltd . All Rights Reserved.