The Eltek Rectiverter Power Core 110 VDC 18 kVA is a versatile power system that combines both AC and DC feeds into a single common unit. It provides AC backup power for 3-phase or single-phase AC loads, and 110 VDC power for DC loads and battery charging. Total output power for both AC and DC output is limited to a maximum of 24 kW, with AC and DC output limits configurable according to the attached load.
The 3-port converter simultaneously provides power for AC and DC loads. During mains outage, the Rectiverter 110/1200 HE feeds AC loads using energy stored in the battery. Part No. CIOR1207.1xxx.
| Max Current | 128 A | Max Capacity | 24 kW |
|---|---|---|---|
| Product Name | Rectiverter Power System | Hold Up Time | >10 ms; VOUT > 41 VDC |
| AC Output | 1 Phase or 3 Phase | Frequency Default | 50 Hz |
| Current Max Per Phase | 28 A | DC Output | 122.5 VDC / 97–145 VDC |
| DC Power | 14 kW Max | Output Features | Short Circuit Proof, Over Voltage Shutdown |
| Models / Ordering Information | 24 kW, 400 V 3ph | |
|---|---|---|
| Product Family | CIOR1207.1xxx | |
| AC Output Data | ||
| Voltage (default) / (adjustable range)1) | 230 VAC / 200–240 VAC; 400 VAC 3-phase (Y) / 346–415 VAC | |
| Frequency (default inverter mode) | 50 Hz (adaptive) | |
| Frequency (settable inverter mode) | 50 Hz, 60 Hz, or last synced 50/60 Hz (adaptive) | |
| Power maximum (continuous / overload <15 s) | 14.4 kW (18 kVA) / 24 kVA | |
| Current maximum/phase (continuous / overload <15 s) | 78 ARMS / 104.4 ARMS | 26 ARMS / 34.8 ARMS |
| Current (maximum) quick trip/phase (20 ms) | 384 A (6 × nominal) | 128 A (6 × nominal) |
| Hold up (voltage dips) before switching to battery | > 5 ms @ 14.4 kW load | |
| THD | < 1.5% at resistive load | |
| Output features | Fuse in L and N, Hot pluggable | |
| DC Output Data | ||
| Voltage (default) / (adjustable range) | 122.5 VDC / 97–145 VDC | |
| Power (maximum @ nominal input) | 14.4 kW2) | |
| Current (maximum @ VOUT ≤ 108 VDC) | 133 A2) | |
| Hold up time, maximum output power | >10 ms; VOUT > 41 VDC | |
| Output features | Short circuit proof, Over voltage shutdown, Bulk DC output connection to M8 bolt | |
| Input Data | ||
| AC Mains Input Voltage | (3-phase Y) 185–275 VAC; (single phase) 320–475 VAC; (3-phase Y) | |
| AC Current/phase (at nominal output voltage) | 84–144 ARMS4) | 28–48 ARMS4) |
| Frequency (default: sync range) | 47–53 & 57–63 Hz | |
| Frequency (settable: sync range) | 47–53 Hz, 57–63 Hz, or both (adaptive) | |
| Power Factor / THD | > 0.99 at 50% load or more / < 3.5% | |
| DC Voltage nominal / extended range (no overload)3) | 102–145 VDC / 90–102 VDC | |
| DC Current (maximum) | 150 A / 216 A during overload (15 s) | |
| Input features | Fuse in L and N, Hot pluggable, Varistor, Hot pluggable; AC input individual screw terminals 10 mm² for L1, L2, L3, or L1, L1, L1 + N & PE; Bulk DC input connection to M8 bolt; Bulk DC battery connection to M8 bolt | |
| Options | ||
| Control and monitoring (see Smartpack2 datasheet) | Smartpack2, including industrial basic & I/O monitor type 2 | |
| 1-pole AC distribution (L connection directly on MCB) | 1–18 pc, 2–20 A, C or B characteristics | 1–18 pc, 2–20 A, C or B characteristics |
| 3-pole AC distribution (L1–L3 connection directly on MCB) | — | 1–6 pc, 2–20 A, C or B characteristics |
1) Adjustable range depends on module type. 2) Maximum power and current depend on input voltage and load conditions. 3) Extended range operation without overload. 4) Depending on module type.